top of page
Siemens-Cerberus-Intelligent-System.png

SIEMENS Cerberus Pro UL

Peripherals and Detectors and Networkable/Stand-alone Fire Alarm Control Panel (FACP)

ECONOMICAL SYSTEM PLANNING

​

SIEMENS Networkable Fire Control Panels provides the ability to expand devices on a larger scale of buildings while the Stand-Alone control panel are suitable to install on smaller application

​

INTELLIGENT FIRE ALARM CONTROL PANELS (FACP)

​

SIEMENS FACP installed with integrated degrade mode, will be automatically activated, ensuring system is in operation.

​

ADVANCED FIRE DETECTORS

​

Advanced smoke detectors with the Advanced Signal Analysis (ASA) technology, is capable of detecting all types of fire and are adaptable to environmental changes, preventing false alarms.

Siemens.png

Cerberus Pro 

Further information regarding SIEMENS Cerberus Fire Protection System

We are the distributors of the SIEMENS Fire Protection system throughout Sabah and Labuan, driven to introduce our clients the state-of-art fire safety technology. SIEMENS, originally based in Germany, has achieved as one of the top distributors of the Cerberus EN systems worldwide, prioritizing the use of economical, modern technology for accuracy in detection and cost-saving future installments.

SIEMENS - PARTNERSHIP.png

CERBERUS FIRE ALARM CONTROL PANEL (FACP)

Stand-alone Control Panel 

  • Cost-effective stand alone panel for smaller applications, connecting up to 50 devices. ​

  • RS485 connection allows installation of remote terminals to review and operate panel.

  • Fast installation and easy servicing.

 

​Networkable Control Panel 

  • For medium to large application, connecting up to 500 devices.

  • Compatible with SIEMENS addressable field devices. 

  • Peer to peer networking allows up to 16 panels to be connected.

DETECTORS AND PERIPHERALS

Standard Fire Detectors

  • Reliable detection, rejects deceptive phenomena (dust, smoke, etc.)

  • Innovative detection algorithms.

  • Wide operating temperature range for demanding applications.

  • Existing wires can be used to save costs on materials/installments. 


Advanced Fire Detectors 

  • Built with the Advanced Signal Analysis (ASA) technology for fast, reliable detection guaranteed for no false alarm.

  • Best installed on sensitive or harsh environments.

  • Adjustable detection profiles making detectors adaptable to its surroundings.

  • 20+ selectable fire detection profiles. 

MODEL OP921

The Siemens OP921 Photoelectric Smoke Detector is a plug-in, two-wire, addressable, photoelectric smoke detector compatible for use with Siemens Model ‘H’-series devices on the same loop with Cerberus PRO fire-alarm control panels or FireFinder XLS FACPs.

 

Programmable. Compatible with Model 8720 / DPU (device programmer / loop tester)

 

Suitable for use in air-duct housings models FDBZ492 and FDBZ492-HR.

 

COMPATIBLE BASES and ACCESSORIES

— DB-11 Detector Mounting Base

— DB-11E Detector Base, small

— DB2-HR Detector Mounting Base with Relay

— RL-HC Remote Alarm Indicator: 4” (10.2 cm) octag.-box mount, red

— RL-HW Remote Alarm Indicator: single-gang box mount, red

— FDBZ492 Addressable Air-Duct Housing

— FDBZ492-HR Addressable Air-Duct Detector with Relay

— LK-11 Base Locking Kit

MODEL  OOHC941

Model OOHC941 is an advanced, multi-criteria fire / carbon monoxide (Co) detector used on Cerberus PRO control panels. Model OOHC941 incorporates a redundant, optical / thermal sensor with a (Co) sensor.

 

Model OOHC941 offers a better alternative to that of ionization detectors and uses an unique forward / backward light-scattering technology that provides state-of-the-art, unparalleled fire detection to the widest range of fire types. Model OOHC941 also provides a high-sensitivity, pre-alarm level meeting NFPA 76 Telco standard as a VEWFD.

MODEL  OH921

The Photoelectric | Thermal (Heat) Detector (Model OH921) is an intelligent, addressable multi-criteria detector that incorporates optical and thermal sensors, and uses signals in a neural network to create an intelligent multi-criteria detector. The encompassing result is a detector that provides enhanced detection to a wide range of products of combustion. Model OH921 is UL 268 7th Ed. listed and incorporates advanced built-in isolation (optionally configurable), which greatly improves reliability, circuit integrity and provides advanced addressable fault finding.

​

  • UL Listed | FM, CSFM Approved

    • UL 268: `Open Area Smoke Detection’

    • UL 268A (Duct) – `Direct-in-Duct’ use

    • UL 521: `Open Area Heat Detection’

    • ULC-S531: `Open Area Smoke Detection’

    • ULC-S539: `Open Area Heat Detection’

    • FM 3230: `Open Area Smoke Detection’

    • FM 3210: `Open Area Heat Detection’

    • CSFM | File: 7272-0067:0258

​

Features:

  • UL 268 7th Edition Listed

  • Built-in isolation (optional configurable)

  • Each detector is self-testing:

    • complete diagnostics performed every 10 seconds

    • self-monitored for sensitivity within UL Listed limits

  • Listed, approved as a heat detector:

    • Rate-of-Rise Detection: 15°F / min. (8.3°C / min.)

    • Fixed: 135°F (57°C)

  • Superior electromagnetic interference (EMI) and radio-frequency interference (RFI) immunity

  • Field programmable as rate-of-rise or fixed temperature, per ‘Alarm Source 2’ | Standard parameter

  • Tri-color detector-status light-emitting diode (LED) with 360° view

  • Compatible with Model 8720 | DPU (device programmer / loop tester)

  • Polarity insensitive via SureWire technology (in non-isolator mode)

  • Functions with Model DB-11–series mounting bases

  • Restriction of Hazardous Substances (RoHS compliant)

  • Automatic environment compensation

MODEL  HI921

The Siemens HI921 Intelligent Heat Detector is a two-wire addressable Heat Detector that features seven (7) field-selectable temperature-range settings: 135°F (57°C) - 174°F (79°C) with fixed and rate-of-rise programmability. Compatible for use with Siemens DPU Device Programmer / Loop Tester.

​

HI921 SIEMENS Intelligent Thermal (Heat) Detector
The Intelligent Thermal (Heat) Detector (Model HI921 Siemens) provides an advanced method of detection, address programming supervision combined with sophisticated FACP communication. Model HI921 uses a state-of-the-art thermistor, microprocessor, and advanced signal analysis, providing high reliability and accuracy.

Additionally, Each Model HI921 unit is UL listed including advanced built-in ISOtechnology - a True Class-X1/2 SLC operation (use is optional) greatly improving system reliability and circuit integrity while providing advanced addressable fault finding.

Each model HI921 is a cost-effective, intelligent, addressable thermal detector that provides distinctive, advanced features: seven (7) field-selectable temperature settings
specially tailored for application-specific detection needs to be combined with Class-X SLC operation built-in avoiding additional installation and material cost.

SINORIX IG541

IG-541 Clean Agent

Fire Suppression System

IG-541 is a clean agent fire suppression containing inert gases, designed to release natural extinguishment gas and suppress fire before damage occurs for safe evacuation.

​

The cylinder combines extinguishment inert gases which are Nitrogen, Argon and Carbon Dioxide. 

​

This particular fire suppression system is controlled by a conventional fire detection designed for gas release.

 

Benefits of IG-541 clean agent :

  • Efficient fire extinguishment and ability to protect large areas up to 100m

  • Pure natural gases, safe for environment and surroundings

  • Cost-efficient as a only single bank is needed on a calculated space

  • No reaction towards harmful substances, toxic or corrosive products

  • Takes up minimal space and great flexibility in design.